TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-174

August 9, 2005

Ka a a

w s k

ERROR CODE P1009

Program is already running.

Main causes include:
1. An attempt is made to edit or execute a program that is running.
2. SYSINIT command is executed while a program is running.

Stop the robot control program prior to editing or checking.

Stop the robot control program prior to executing the SYSINIT command.

_____________________________________________________________________

ERROR CODE P1010

Robot control program is already running.

Occurs when an attempt is made to execute a DO, TOOL, or BASE command when a
robot control program is running.

Wait for the robot control program to complete execution.

Stop the robot control program.

_____________________________________________________________________

ERROR CODE P1011

Cannot continue this program. Use EXECUTE.

After a program is executed the specified number of times in repeat mode, the CON-
TINUE command is entered or the CYCLE START switch is pressed.

The CONTINUE command or CYCLE START switch cannot be used at this time, use
the EXECUTE command to start the program.

Re-select the program and press the CYCLE START switch.

_____________________________________________________________________

ERROR CODE P1012

Robot is moving now.

Displayed if any of the following commands are entered while a program is running:
EXECUTE, CONTINUE, TOOL, BASE, DO. SYSINIT or CYCLE START.

Stop the program or confirm the operation to be performed.

_____________________________________________________________________

ERROR CODE P1013

Cannot execute because in error now. Reset error.

Occurs when attempt is made to start robot motion before an error has been cleared.

Clear any errors and re-enter the command.

_____________________________________________________________________