TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-40

August 9, 2005

Ka a a

w s k

ERROR CODE D1512

Brake line error for JtXX.

This error occurs when the 1KB board detects an error signal sent from the brake re-
lease control MOSFET on the 1KQ/1NR board.

Transformer

Circuit breaker

MOSFET

Voltage

monitoring

1KP board

Motor

1KB board

Robot

Controller

Safety circuit

Brake power supply error signal

Brake release signal

Brake line error signal

1KQ/1NR board

+24 VDC

Brake power supply D3X

Brake power supply D7X

Motor br

ak

e line

Brake line errors are not detected during motor power OFF. Brake line disconnection is
not detected during automatic operation. Brake line error detection timing is shown in
the diagram below.

Motor power

Servo control

Brake release

ON

START

RELEASE

Disconnection

detected

Short-circuit

detected

Main causes include:
1. Disconnection/short-circuit/ground fault/poor connection at the brake line axis motor

harness.

2. Defective connection for the brake power line.
3. Defective connection or harness between the 1KB and 1KQ/1NR boards.
4. Defective connection or harness between the 1KB and 1KX/1NX boards.
5. Defective connection or harness between the 1NR and 1NX boards.
6. Incorrect 1KP board safety circuit setting.
7. Defective 1KB or 1KQ/1NR board.

Check for disconnection or short-circuit in the motor harness, and repair or replace as