Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 76

Advertising
background image

TROUBLESHOOTING

1-73

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

6. Malfunction of the motor.
7. Servo spot weld gun:

–Clamping pressure and/or clamping time is excessive.
–Distance between weld points is short; the motor does not have time to cool suffi-

ciently between welds.

–Clamping pressure setting exceeds the servo gun motor power capacity.

Check the cyclo reduction unit, the gear, or the bearing(s) for mechanical failure.
Replace as necessary.

Re-teach the robot motion as necessary.

Check the harness and servo unit for electrical malfunctions and replace if necessary.

Replace the 1KB board.

Replace the 1KQ/1NR board.

Servo Spot Weld Gun

If the weld points are close to each other, set a time delay. This provides a cool-down
period for the servo gun motor.

Set the clamping force lower (see servo gun manufacturer’s specifications).

_____________________________________________________________________