background image

TROUBLESHOOTING

1-191

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE P2055

[LSEQ] Program is already running.

During execution of the basic operation part of the sequence function of the KLogic
program, the program is executed again by the LSQEXECUTE command/instruction.

Place the basic operation part of the sequence function in HOLD and re-execute.

Correct the currently running program using the LSQREWRITE command.

_____________________________________________________________________

ERROR CODE P2056

[LSEQ] No. of signal is outside specifiable range.

The basic operation part of the KLogic program includes an instruction that specifies an
invalid signal number as an argument.
Example: LSQ STR, &X0800.

Ensure valid signal numbers are used in the KLogic program

.

Example: LSQ STR,&X07FF.

_____________________________________________________________________

ERROR CODE P2057

[SerialFlash] cannot open file.

A file stored on the 1KA board cannot be opened.

Main cases include:
1. The file is corrupt.
2. An attempt to save is made, but the 1KA board serial flash memory is set to write-

protect.

Ensure the 1KA board serial flash memory is not set to write-protect

.

Replace the 1KA board serial flash memory.

_____________________________________________________________________

ERROR CODE P2058

[SerialFlash] data read error.

A file on the 1KA board cannot be read because the file is corrupt.

Replace the 1KA board serial flash memory.