Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 77

Advertising
background image

TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-74

August 9, 2005

Ka a a

w s k

ERROR CODE E1029

Encoder rotation data is abnormal. (Jt XX)

Occurs when there is a difference (+2 rotations or more) between the rotation data in
the serial encoder data and the rotation data calculated using the incremental tech-
nique.

Power
circuit

Battery

Encoder

Encoder

1FG/1HG board

Robot

Controller

1KB board

Encoder I/F

Servo

CPU

Encoder +12 VDC power supply

Check connections at encoder, 1FG/1HG board, and separation harness.

Check for noise and shield integrity.

Ensure the 1KB board is properly seated into the card rack.

Check for continuity in the machine harness and separation harness.

Replace 1FG/1HG board.

Replace the 1KB board.

Replace the encoder.

For additional information on error code E1029, see section 1.4.