TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-168

August 9, 2005

Ka a a

w s k

ERROR CODE P0144

Step:XX Preceding IF missing.

Displayed when control flow structure does not contain the correct structure for
IF…THEN… ELSE…END commands.

Use correct syntax and components in control flow structures.

_____________________________________________________________________

ERROR CODE P0145

Step:XX Preceding CASE missing.

Displayed when control flow structure does not contain the correct structure for
CASE…OF… VALUE…ANY…END commands.

Use correct syntax and components in control flow structures.

_____________________________________________________________________

ERROR CODE P0146

Step:XX Preceding DO missing.

Displayed when control flow structure does not contain the correct structure for
DO…UNTIL.

Use correct syntax and components in control flow structures.

_____________________________________________________________________

ERROR CODE P0147

Step:XX Cannot find END of XX.

Occurs when control flow structure that requires an END statement does not contain the
necessary END.

Use correct syntax and components in control flow structures.

_____________________________________________________________________

ERROR CODE P0148

Step:XX Too many control structures.

Occurs when 10 layers of control flow structure are exceeded.

Limit control flow structure to 10 layers.

_____________________________________________________________________