TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-184

August 9, 2005

Ka a a

w s k

ERROR CODE P2016

Cannot open the file.

The file cannot be opened with the SAVE or LOAD commands.

Ensure the floppy disk is properly inserted into the floppy disk drive.

Ensure an existing file name is used.

Defective local bus harness.

Defective floppy disk, floppy disk drive unit, or 1KA board.

_____________________________________________________________________

ERROR CODE P2017

Cannot close the file.

A file opened by the SAVE or LOAD command cannot be closed.

If the file is opened using a PC, ensure proper connection with the controller.

Defective local bus harness.

Defective floppy disk, floppy disk drive unit, or 1KA board.

_____________________________________________________________________

ERROR CODE P2019

ADC function already in use.

This error occurs when a monitor command and a program command are executed for
an ADC function at the same time.

Do not execute a monitor command for an ADC function while a robot or process
control program is executing an ADC function command.

_____________________________________________________________________

ERROR CODE P2020

Illegal device number.

For Host Communication I, the sensor port is specified as logical device number 1 or 7.
The PC terminal port is specified as logical device number 2 or 8. This error occurs
when a SEND command/instruction specifies an illegal device number.
Example: SEND 3:$out,err.

Ensure an available device number is specified.

Example: SEND 1:$out,err.

_____________________________________________________________________