TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-36

August 9, 2005

Ka a a

w s k

ERROR CODE D1508

24VDC power source is too low.

24 VDC to the power sequence board has dropped to +21.6 VDC or less.

Mother Board

1KP board

1KB board

1KX board

EPLD

24 VDC

monitor

AVR for

control power

Main

disconnect

Primary

power

Control

power

210 VAC

DC error

signal

Local

bus

F1

T1

F3

1KQ/1NQ board

Transformer

Circuit

breaker

Main causes include:
1. Defective AVR for control power supply.
2. Defective 1KP board.
3. Defective 1KQ/1NQ board.
4. Short circuit in the motor power on circuitry, the EMERGENCY STOP switch, or axis

restriction limit switch circuits.

5. Short in machine valve and sensor circuits.

Check the power supply, machine valve, and the sensor circuits for short circuits.

Ensure the 24 VDC load does not exceed the power supply capacity.

Check the AVR, the 1KP power sequence board, and the 1KQ/1NQ relay board and
replace as necessary.