Check the avr and nfb f1 and replace as necessary, Confirm supply power is within specifications, Replace the 1kp board – Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 41: Replace the 1kq/1nq board

Advertising
background image

TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-38

August 9, 2005

Ka a a

w s k

ERROR CODE D1510

Primary power source is too low.

Voltage level of the AVR primary power supply is too low (150-158 VAC or less for 1-2
sec.).

Mother Board

1KP board

1KB board

1KX board

EPLD

AVR for

control power

Main

disconnect

Primary

power

Control

power

210 VAC

AC error

signal

Local

bus

F1

T1

F3

1KQ/1NQ board

Transformer

Circuit

breaker

Main causes include:
1. Drop in the primary power supply voltage.
2. Defective AVR.
3. Defective NFB F1.
4. Defective 1KP power sequence board.
5. Defective 1KQ/1NQ relay board.
6. Power supply circuit problem.

Verify the power supply to the controller is within ratings.

Check the AVR and NFB F1 and replace as necessary.

Confirm supply power is within specifications.

Replace the 1KP board.

Replace the 1KQ/1NQ board.