ERROR CODE E1143

Conveyor axis number is not set.

Conveyor axis number is not set at execution of conveyor synchronous motion.

Set the conveyor axis number using the ZCVAXIS instruction

.

_____________________________________________________________________

ERROR CODE E1144

No arm control board.

Ensure the 1KB arm control board is properly installed.

Replace the 1KB board.

Replace the 1KA board.

_____________________________________________________________________

ERROR CODE E1145

Cannot use specified channel, already in use.

Several “WHERE” commands were executed at the same time.

Do not execute unnecessary “WHERE” commands.

_____________________________________________________________________

ERROR CODE E1146

[LESQ] Aborted by process time over.

KLogic program did not complete execution within the specified time.

Contact KRI customer service (include operating conditions/settings and operation
log at the time the error occurred)

.

_____________________________________________________________________

ERROR CODE E1147

Cannot open setting file, so cannot set to shipment state.

When “2: Setting to shipment state” is selected from the initialization screen, there is no
setting file (ini_load.cmd) in the 1KA board memory.

Load the setting file

(ini_load.cmd)

into the 1KA board memory

.

_____________________________________________________________________

ERROR CODE E1148

Cannot read setting file, so cannot set to shipment state.

When “2: Setting to shipment state” is selected from the initialization screen, the setting
file (ini_load.cmd) in the 1KA board memory could not be decoded.

Ensure the proper setting file

(ini_load.cmd)

is loaded into the 1KA board memory

.

_____________________________________________________________________