TROUBLESHOOTING

1-93

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE E1081

Cannot use negative value.

Displayed when a negative number is used in conjunction with the PULSE or
ACCURACY commands/instructions.

Use only positive numbers in the acceptable range for the PULSE and ACCURACY
commands/instructions.

_____________________________________________________________________

ERROR CODE E1082

Out of absolute lower motion range limit.

Displayed when an attempt is made to set the software lower limits of robot travel to a
value that is beyond the robots lower limit (LLIMIT command).

Set lower software travel limits to an acceptable value.

_____________________________________________________________________

ERROR CODE E1083

Out of absolute upper motion range limit.

Displayed when an attempt is made to set the software upper limits of robot travel to a
value that is beyond the robots upper limit (ULIMIT command).

Set upper software travel limits to an acceptable value.

_____________________________________________________________________

ERROR CODE E1084

Out of set lower motion range limit.

Data used is beyond the lower limit set in AUX 0507.
Example:
Data used for the SETHOME command is beyond the lower limit set in AUX 0507.

Set motion range within the motion range limits set in AUX 0507.

Set lower software travel limits to an acceptable range (confirm safe operation).

_____________________________________________________________________

ERROR CODE E1085

Out of user upper limit.

Data used is beyond the upper limit set in AUX 0507.
Example:
Data used for the SETHOME command is beyond the upper limit set in AUX 0507.

Set motion range within the motion range limits set in AUX 0507.

Set upper software travel limits to an acceptable range (confirm safe operation).

_____________________________________________________________________

Advertising