TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-76

August 9, 2005

Ka a a

w s k

ERROR CODE E1031

Miscount of encoder data (Jt XX).

The servo gun or tool changer harness is defective.

Inspect the servo gun and tool changer harnesses; replace if necessary.

_____________________________________________________________________

ERROR CODE E1032

Mismatch ABS and INC encoder data (Jt XX).

Occurs when there is a large difference between the value in the serial encoder data
and the calculated data using the incremental technique.

Power
circuit

Battery

Encoder

Encoder

1FG/1HG board

Robot

Controller

1KB board

Encoder I/F

Servo

CPU

Encoder +12 VDC power supply

Main causes include:
1. Defective encoder or encoder harness.
2. Defective 1KB board.
3. Noise related malfunction.
4. Defective 1FG/1HG board.
5. Servo spot weld gun.

–Loose connection at tool changer.
–Defective tool changer harness.

Replace encoder, replace 1KB board.

Check connections at encoder, 1FG/1HG board, and separation harness.

Ensure the 1KB board is properly seated into the card rack.

Check for continuity in the machine harness and separation harness.

Check for noise and shield integrity.

Replace 1FG/1HG board.

For additional information on error code E1032, see section 1.4.

_____________________________________________________________________