TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-160

August 9, 2005

Ka a a

w s k

ERROR CODE P0106

Illegal priority.

Priority level designation is out of the allowable range

(1–127)

.

Example: LOCK 128

Ensure the correct priority level number is entered (1–127).
Example: LOCK 2

_____________________________________________________________________

ERROR CODE P0107

Invalid coordinate value.

Upper limit value is less than lower limit value for work space output data.

Enter the correct upper limit coordinates.

_____________________________________________________________________

ERROR CODE P0108

Syntax error.

Occurs when an AS Language command is entered that does not follow the correct
syntax.

Correct the syntax, format or spelling of the command/instruction.

_____________________________________________________________________

ERROR CODE P0109

Invalid statement.

Main causes include:
1. An AS Language command is entered that has typing errors, incorrect spelling or is in

the wrong format.

2. An existing variable name, that is already used for a variable of a different type, is

used.

Correct the syntax, format or spelling of the command/instruction.

Do not use existing variable names.

_____________________________________________________________________

ERROR CODE P0110

Specify full spelling of command.

Displayed when an abbreviation is entered incorrectly or has missing letters.

Enter the correct abbreviation or use the full spelling of the command.

_____________________________________________________________________

Advertising