TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-90

August 9, 2005

Ka a a

w s k

ERROR CODE E1067

Illegal pattern type.

Main causes include:
1. Program step does not comply with AS Language syntax.
2. Pattern type for work specified using block step instructions or the PALLET function is

not between 1 and 5.

Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.

Ensure the work pattern number specified is correct.

_____________________________________________________________________

ERROR CODE E1068

Illegal work data.

Main causes include:
1. Program step does not comply with AS Language syntax.
2. Work data specified using block step instructions or the PALLET function is incorrect

or not registered.

Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.

Ensure the work data specified is correct.

_____________________________________________________________________

ERROR CODE E1069

Illegal pallet data.

Main caused include:
1. Program step does not comply with AS Language syntax.
2. Pallet data in a block step program, the PALUP instruction or the PALLET function, is

incorrect or not registered.

Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.

Ensure the pallet data specified is correct.

_____________________________________________________________________

ERROR CODE E1070

ON/ONI signal is already input.

An ON/ONI instruction mode “/ERR” is specified and the signal condition to monitor is
already attained when monitoring starts.

Delete the “/ERR” mode from the ON/ONI instruction or specify “/LVL” mode

.

Modify the program so the signal condition is not attained until monitoring starts.

_____________________________________________________________________

Advertising