CIO Area Allocations

Section 4-2

Bit

Name

Status

Manipulated

by

Unit operation

0

Unit Error Occurred

ON

Unit

Indicates that an error
occurred that is related to
EtherNet/IP Unit operation.

This flag is turned ON when
any bit in Unit Status 1 is
ON. (Bits 1 to 15 are logi-
cally ORed.)

OFF

Unit

Indicates that a Unit error
did not occur. This flag is
turned OFF when the error
is cleared.

1

Network Error
Occurred

ON

Unit

One or more network-
related errors occurred.
(The bits in Communica-
tions Status 1 and 3 are log-
ically ORed.)

OFF

Unit

Indicates that a network
error did not occur. This flag
is turned OFF when the
error is cleared.

2 to 3

(Not used)

---

---

---

4

Unit Memory Error

ON

Unit

Indicates that an error
occurred in accessing the
Unit’s internal non-volatile
memory (device error).

OFF

Unit

Indicates that a non-volatile
memory error did not occur.
This flag is not cleared even
if it occurs one time. (Flag
remains ON.)

5

Communications
Controller Error

ON

Unit

Indicates that an error
occurred in the communica-
tions controller.

OFF

Unit

Indicates that a communica-
tions controller error did not
occur. This flag remains ON
until the power supply is
turned OFF and ON again.

6

IP Address Duplica-
tion Error

ON

Unit

An ARP was sent with the
specified IP address, indi-
cating that an IP address
duplication was detected.
An address duplication is
detected if there is an ARP
response. This flag remains
ON until the power supply is
turned OFF and ON again.

(The Ethernet interface will
stop.)

OFF

Unit

There was no ARP
response.

7 to 8

(Not used)

---

---

---

9

Link OFF Error

ON

Unit

There was an error estab-
lishing a link with the switch-
ing hub.

OFF

Unit

A link was established nor-
mally with the switching hub.