FINS Commands Addressed to EtherNet/IP Units or Built-in EtherNet/IP Ports

Appendix E

Remote Port Number (4 bytes)
The remote port number allocated to the socket.

TCP Transitions (4 bytes)
The TCP connection status is returned as one of the numbers shown in the following table. Refer to Appendix
C TCP Status Transitions
for a diagram of transitions.

Precautions

All the above values are set to 0 if Ethernet communications functions are stopped due to improper settings in
the system setup.

Response Codes

ADDRESS INFORMATION READ

Reads FINS node addresses and IP addresses

Command Block

Response Block

Parameters

Number of Addresses (Response)

Returns the number of pairs of FINS node addresses and IP addresses. With the EtherNet/IP Unit or built-in
EtherNet/IP port, this value is always 0001 (1 decimal).

Number

Stage

Status

00 00 00 00

CLOSED

Closed.

00 00 00 01

LISTEN

Waiting for connection.

00 00 00 02

SYN SENT

SYN sent in active status.

00 00 00 03

SYN RECEIVED

SYN received and sent.

00 00 00 04

ESTABLISHED

Already established.

00 00 00 05

CLOSE WAIT

Received FIN, waiting to close.

00 00 00 06

FIN WAIT 1

Completed and FIN sent.

00 00 00 07

CLOSING

Completed and exchanged FIN. Awaiting ACK.

00 00 00 08

LAST ACK

FIN sent and completed. Awaiting ACK.

00 00 00 09

FIN WAIT 2

Close completed and ACK received. Awaiting FIN.

00 00 00 0A

TIME WAIT

After closing, pauses twice the maximum segment life (2MSL).

Response code

Description

0000

Normal end

1001

Command too large

27 65

Command

code

27 65

Number

of addresses

Address

information

Response

code

Command

code

6 bytes