2-17 checking connections, Checking connections – Omron SYSMAC CJ1W-EIP21 User Manual

Page 206

Advertising
background image

180

Setting Tag Data Links

Section 6-2

5.

Select any of the options as necessary. The options are listed below.

Note

The save format will vary depending on the Network Configurator version.
Configuration files (*.ncf) created using the Network Configurator for Ether-
Net/IP (version 2 or higher) can be imported (opened) by selecting External
Data - Import
from the File Menu.

6-2-17 Checking Connections

Check the consistency of connection parameters for network configuration
files with device parameters set using the Network Configurator and device
parameters uploaded from the network.

1.

Select Check Connections in the Network Menu. The following dialog box
will be displayed if parameters are normal.

The following dialog box will be displayed if there are parameter errors.
Check the displayed details and review the settings.

If an inconsistency occurs, open the originator's Edit Device Parameter Di-
alog Box and click the Connection Tab. The inconsistent connection will

be displayed with a

icon (instead of the normal

icon). To change

the connection setting and select a different target variable, select the con-
nection as shown below and click the Edit Button.

Option

Function

Select target network

Allows you to select specific networks from the net-
work configuration and open them.

Add to current document

Allows you to add the networks from the network
configuration file being opened to the current config-
uration file.

Advertising
This manual is related to the following products: