405

FINS Commands Addressed to EtherNet/IP Units or Built-in EtherNet/IP Ports

Appendix E

Response Codes

Precautions

• The local IP address and subnet mask set by this command are written to the CPU Bus Unit System Setup

for the EtherNet/IP Unit or built-in EtherNet/IP port.

• The new local IP address and subnet mask settings will become effective when the PLC or EtherNet/IP

Unit or built-in EtherNet/IP port is restarted.

IP ADDRESS TABLE READ

Reads the IP address table.

Command Block

Response Block

Parameters

Number of Records (Command, Response)

The number of records to read is specified between 0000 and 0020 (0 to 32 decimal) in the command. If this
value is set to 0, the number of stored records is returned but the IP address table records are not returned.
The response returns the actual number of records read.

Maximum Number of Stored Records (Response)

The maximum number of records that can be stored in the IP address table is returned. The maximum number
of stored records is fixed at 0020 (32 records).

Number of Stored Records (Response)

The number of IP address table records stored at the time the command is executed is returned as a hexadec-
imal number.

IP Address Table Records (Response)

The number of IP address table records specified in the number of records parameter is returned. The total
number of bytes in the IP address table records is calculated as the number of records

×

6 bytes/record. The

configuration of the 6 bytes of data in each record is as shown in the following diagram.

Response code

Description

0000

Normal end

1001

Command too large

1002

Command too small

Number of

records

Command

code

27 60

Maximum

number

of stored

records

Number

of stored

records

Number

of records

IP address

table records

Response

code

Command

code

27 60

IP address

table records

6 bytes

6 bytes