326

Using the Automatic Clock Adjustment Function

Section 12-2

12-2-2 Settings Required for Automatic Clock Adjustment Function

The following settings must be set in the Unit Setup when using the automatic
clock adjustment function.

Note

When the Server specification type field in Auto Adjust Time Tab is set to Host
name
.

CX-

Programmer

tab

Settings

Setting conditions

Reference

Auto Adjust
Time

Server specification
type

Required.

12-2-3 Auto Adjust
Time
on
page 327

IP Address

One or the other is
required, depending
on the Server specifi-
cation type
setting.

Host name

Port No.

Rarely required.
(Change when a set-
ting other than the
default setting of 123
is required.)

Get the time informa-
tion from the SNTP
server

Required.

Auto Adjust Time

Optional

Retry timer

Optional (Change
when the default set-
ting of 10 seconds is
unacceptable.)

Adjust Time

Optional

DNS (See
note.)

IP Address

Required.

3-8 TCP/IP and Link
Settings
on page 52

Port No.

Rarely required.
(Change when a set-
ting other than the
default setting of 53
is required.)

Retry timer

Optional (Change
when the default set-
ting of 10 seconds is
unacceptable.)