Connection Status Codes and Error Processing

Section 14-3

01

0316

Error code returned from target:

There was a parameter error in
the frame used to close the con-
nection.

This error does
not occur.

Depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)

Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)

01

031C

Error code generated in origina-
tor:

Some other error occurred.

This error does
not occur.

The originator gener-
ates this code when
an unsupported
response code is
returned from the
target in reply to a
connection-opening
request.

Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)

08

---

Error code returned from target:

There is no Forward Open or
Large Forward Open service in
the target device.

This error does
not occur.

Depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)

Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)

D0

0001

Error code generated in origina-
tor:

The connection operation is
stopped.

The connection
was stopped
because the Tag
Data Link Stop Bit
was turned ON, or
the settings data
is being down-
loaded.

Either turn ON the
Tag Data Link
Start Bit, or wait
until the settings
data has been
downloaded.

Includes Control-
ler stop errors,
Unit failure, and
EM bank files at
the refresh desti-
nation. To handle
these errors, refer
to 14-2-1Errors
Occurring at the
EtherNet/IP Unit
or built-in Ether-
Net/IP port
.

The meaning of this
error code is defined
by each vendor, so it
depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)

Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)

D0

0002

Error code generated in origina-
tor:

The connection is being opened
(opening processing in
progress).

Wait until the
opening process-
ing is completed.

The meaning of this
error code is defined
by each vendor, so it
depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)

Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)

Connection status

Source of error

Handling

General

Status

(hex)

Additional

Status

(hex)

Configuration 1

Configuration 2

Configuration 3

Advertising