Omron SYSMAC CJ1W-EIP21 User Manual

Page 82

Advertising
background image

56

TCP/IP and Link Settings

Section 3-8

2.

Select Tools - Setup TCP/IP Configuration to display the following Setup
TCP/IP Configuration Dialog Box, and set the TCP/IP Configuration for the
target device. In the following example, the settings are all at their default
values.

3.

Enter the IP address to set and press the Get from the Device Button. The
present setting will be obtained. Change the IP address in the New Con-
figuration
Box if required.

4.

Press the Set to the Device Button. The IP address will be transferred to
the device. The applicable device is the device specified in the Target IP
Address
Box. The device must be reset to enable the transferred setting. If
the device is not reset when the new IP address is transferred, click the Re-
set the Device
Button.
When the EtherNet/IP Unit is reset, the IP address will be displayed once
in flowing text on the 7-segment display on the front of the Unit.

Note

(1) The transfer function for IP address settings is defined by ODVA specifi-

cations. Target devices that do not support these specifications cannot be
set. When setting the IP address of the target device with the Network

Advertising
This manual is related to the following products: