Private and Global Addresses

Section 5-3

5-3-2

Using a Private Address for the EtherNet/IP Unit

Conditions for Using
Communications
Applications

When the EtherNet/IP Unit or built-in EtherNet/IP port has a private address,
communications applications can be used under the following conditions:

FINS Communications Service

• The FINS communications service can be executed on the intranet

between EtherNet/IP Units and built-in EtherNet/IP ports with private
addresses only.
A device such as a personal computer (with a FINS application, including
the CX-Programmer) cannot connect online and communicate over the
Internet with an EtherNet/IP Unit or built-in EtherNet/IP port that has a pri-
vate address. FINS communications are also not possible over the Inter-
net between EtherNet/IP Units and or built-in EtherNet/IP ports with
private addresses.

• Either FINS/TCP or FINS/UDP can be used for the FINS communications

service.

• With FINS/UDP, all of the EtherNet/IP Unit or built-in EtherNet/IP port IP

address conversion methods can be used.

Intranet

FINS/TCP client computer
with CX-Programmer, etc.

Firewall

IP router

Ethernet (EtherNet/IP)

PLC

Communications in intranet

EtherNet/IP Unit: Private address

FINS communications,
Explicit messages

FINS communications,
Explicit messages

Internet

Intranet

IP router

Firewall

Communications in Intranet

FINS/TCP client computer
with CX-Programmer, etc.
or
CIP client computer with
Network Configurator, etc.

Ethernet (EtherNet/IP)

PLC

PLC

Communications
in Intranet

EtherNet/IP Unit: Private address

EtherNet/IP Unit: Private address

or
CIP client computer with
Network Configurator, etc.