Tag Data Link Performance for CJ2M Built-in EtherNet/IP Ports

Section 10-4

10-4 Tag Data Link Performance for CJ2M Built-in EtherNet/IP

Ports

10-4-1 Overview

The built-in EtherNet/IP port on a CJ2M CPU Unit (CJ2M-CPU3

@

) supports

tag data links for up to 32 connections, with a data size of 20 words per con-
nection. These specifications are different from those of CJ2H built-in ports
and EtherNet/IP Units. The maximum number of words that can be transmit-
ted for tag data links is 640 words. This 640 words is the amount of data that
is processed for one data transmissions between the CPU Unit and the CJ2M
built-in port.

The tag data link specifications of CJ2M built-in ports are provided in the fol-
lowing table. If these specifications are insufficient for the required system
configuration, use a CJ2H built-in port on a CJ2H-CPU6

@

-EIP CPU Unit or a

CJ1W-EIP21 EtherNet/IP Unit.

Tag Data Link Specifications for CJ2M Built-in EtherNet/IP Ports

Tag Data Link System
Configuration
Example

This example configuration is based on the maximum specifications for CJ2M
built-in ports where all nodes send and receive data to the other nodes. In this
case, the maximum send area for each node in a 17-node configuration is 20
words.

For example, node 1 establishes 16 send connections and 16 receive connec-
tions to the other 16 nodes, for a total of 32 connections. The maximum data
size per connection is 20 words, so the send area in node 1 is 20 words and
the receive areas in node 1 are each 20 words.

CJ2M built-in port

(CJ2M-CPU3

@

)

Reference: CJ2H built-in port

(CJ2H-CPU6

@

-EIP)

Number of connections

32

256

Packet interval (RPI)

1 to 10,000 ms (in 0.5-ms units)

0.5 to 10,000 ms (in 0.5-ms units)

Allowed communications
bandwidth per Unit (PPS)

3,000 pps

6,000 pps

Number of tags that can be
registered

32

256

Tag types

CIO Area, DM Area, EM Area, Holding Area, Work Area, and network symbols

Number of registrable tag sets 32

256

Number of tags per connec-
tion

8 (7 tags when the tag set contains the PLC status)

Maximum size of 1 tag set

20 words

(The PLC status uses 1 word when the tag
set contains the PLC status.)

722 words

(The PLC status uses 1 word when the tag
set contains the PLC status.)

Maximum data size per con-
nection

20 words

722 words

Maximum link data size per
node

640 words

184,832 words

Maximum number of tags that
can be refreshed per CPU Unit
cycle

Output/Transmission
(CPU

EtherNet/IP): 32

Input/Reception (EtherNet/IP

CPU): 32

Output/Transmission
(CPU

EtherNet/IP): 256

Input/Reception (EtherNet/IP

CPU): 256

Data that can be refreshed per
CPU Unit cycle

Output/Transmission (CPU

EtherNet/IP):

640 words

Input/Reception (EtherNet/IP

CPU):

640 words

Note The total for output/transmission and

input/reception is 640 words.

Output/Transmission (CPU

EtherNet/IP):

6,432 words

Input/Reception (EtherNet/IP

CPU):

6,432 words

Note The total for output/transmission and

input/reception is 12,864 words.