TCP/IP and Link Settings

Section 3-8

3-8

TCP/IP and Link Settings

This section describes the TCP/IP-related settings, such as the local IP
address and subnet mask for the EtherNet/IP Unit or built-in EtherNet/IP port.
Use the CX-Programmer to make these settings. The settings are stored in
non-volatile memory in the Unit.

Note

Unlike the Ethernet Units, the TCP/IP settings of the EtherNet/IP Unit and
built-in EtherNet/IP port are not stored in the CPU Unit’s CPU Bus Unit Sys-
tem Setup Area.

3-8-1

Setting Procedure with the CX-Programmer

1,2,3...

1.

When the EtherNet/IP Unit is registered in the I/O tables of the CX-Pro-
grammer, the EtherNet/IP Unit and built-in EtherNet/IP port will be dis-
played in the I/O tables. Refer to

3-6 Creating I/O Tables

for details.

2.

Right-click the EtherNet/IP Unit or built-in EtherNet/IP port in the I/O table
and select Edit - Unit Setup from the menus. The Edit Parameters Dialog
Box will be displayed.

3.

Make the necessary settings on the TCP/IP Tab Page of the Edit Parame-
ters Dialog Box. (The IP address is set here.)