185

Ladder Programming with Tag Data Links

Section 6-3

Programming for Revision 1 or Higher

Example of Programming
to Process Data

The following type of programming can be used to process data only when the
data links are operating normally.

Interlocks (IL and ILC instructions) and jumps (JMP and JME instructions) can
also be used to process data only when the data links are operating normally
as shown below.

Tag Data Link

Operating

n+11 bit 01

Unit Error

Occurred

n+10 bit 00

Unit Error

Occurred

n+10 bit 00

10000

Local node
Error output

Release Flag

Local node

Error output

DIFD

10000

DIFU

10000

The parts of the ladder program
that use the data link area for
the relevant node are processed
only when the corresponding
Normal Operation Flag is ON.

Normal Operation

Flag

Additional part

Normal Operation

Flag

Node A data processing

Node A Data Link
Normal Operation Flag

IL

ILC

Node B data processing

Node B Data Link
Normal Operation Flag

IL

ILC

Node C data processing

Node C Data Link
Normal Operation Flag

IL

ILC