5-2 finsgateway, Finsgateway – Omron SYSMAC CJ1W-EIP21 User Manual

Page 241

Advertising
background image

215

Using FINS Applications

Section 8-5

8-5-2

FinsGateway

FinsGateway Ver. 2003 must be used to communicate using FINS/TCP
between applications serving as communications drivers and CS1W-EIP21,
CJ1W-EIP21, CJ2H-CPU

@@

-EIP, or CJ2M-CPU3

@

EtherNet/IP Units.

FinsGateway Ver. 3.

@

or lower versions can be used, however, when commu-

nicating by the FINS/UDP method only.

Overview of Setup Methods

1. Starting FinsGateway Settings

Select FinsGateway

FinsGateway Setup to start the FinsGateway Setup.

2. ETN_UNIT Driver Setup

1.

Double-click on ETN_UNIT in the settings for the network and Unit. The fol-
lowing ETN_UNIT Properties Window will be displayed.

• Network Tab Page

• Network number

Set the network number for the personal computer
(Ethernet port).

• Local node address

Set the personal computer (Ethernet port) node
address (1 to 254) on the Ethernet network.

• Communication unit number

Set the unit number in decimal (16 to 31) for the per-
sonal computer (Ethernet port).