Omron SYSMAC CJ1W-EIP21 User Manual

Page 101

Advertising
background image

75

CIO Area Allocations

Section 4-2

Unit Status 2
(EtherNet/IP Unit to
CPU Unit) (n + 11)

10 to
13

(Not used)

---

---

---

14

Status Area Layout
Setting Error

ON

Unit

Indicates that there was an
error in the allocated CIO
Area’s layout settings. When
this error occurs, the allo-
cated CIO Area layout is set
to the default pattern.

In the following cases, how-
ever, the allocated CIO Area
layout is set to the user-set
pattern. In this case, the
user-set area will not be
refreshed.

• A non-existent area has

been specified.

OFF

Unit

There was not an error in
the layout settings.

15

(Not used)

---

---

---

Bit

Name

Status

Manipulated

by

Unit operation

Bit

Name

Status

Manipulated

by

Unit operation

0

Online

ON

Unit

Indicates that the Unit is
online. (The EtherNet/IP Unit
can perform communications
processing.)

OFF

Unit

Indicates that the Unit is not
online. This bit is turned OFF
in the following cases.

• IP Address Duplication Error
• Ethernet Communications

Controller Error (hardware
error)

• BOOTP Server Error

Tag Data Link Operating

Operating IP Address Change

Multiple Switches ON Error

Online

User Settings Area Enabled

Error Log Stored

n+11

15 14

13

12

11

10

9

8

7

6

5

4

3

2

1

0