Omron SYSMAC CJ1W-EIP21 User Manual

Page 113

Advertising
background image

87

User Settings Area

Section 4-4

Target Node PLC
Error Information
(EtherNet/IP Unit to
CPU Unit)

These flags indicate the error status (logical OR of fatal and non-fatal errors)
of the target node PLCs, and are valid only when the EtherNet/IP Unit is the
originator. The flags are valid only when the corresponding Normal Target
Node Flag is ON. If the corresponding Normal Target Node Flag is OFF, the
Target Node PLC Error Flag indicates the previous error status.

For details on the default settings, refer to 4-2-2 Details of the Allocated CIO
Area Words
.

Bit

Name

Status

Manipulated

by

Unit operation

---

Target Node PLC
Operating Flags

ON

Unit

The corresponding PLC is oper-
ating. (The program is being exe-
cuted.)

OFF

Unit

The PLC is not operating.

15 14 13 12 11 10 9 8

7

6 5

4

3

2

1

0

+32

15 14 13

12 11 10 9 8 7 6 5 4 3 2 1

0

+33

31 30 29

28 27 26 25 24 23

22 21 20 19

18

17 16

+34

47 46 45

44 43 42 41 40 39

38 37 36 35

34

33 32

+35

63 62 61

60 59 58 57 56 55

54 53 52 51

50

49 48

+36

79 78 77

76 75 74 73 72 71

70 69 68 67

66

65 64

+37

95 94 93

92 91 90 89 88 87

86 85 84 83

82

81 80

+38

111

110

109

108 107

106

105

104

103

102

101

100

99

98

97 96

+39

127

126

125

124 123

122

121

120

119

118

117

116

115

114 113 112

+40

143

142

141

140 139

138

137

136

135

134

133

132

131

130 129 128

+41

159

158

157

156 155

154

153

152

151

150

149

148

147

146 145 144

+42

175

174

173

172 171

170

169

168

167

166

165

164

163

162 161 160

+43

191

190

189

188 187

186

185

184

183

182

181

180

179

178 177 176

+44

207

206

205

204 203

202

201

200

199

198

197

196

195

194 193 192

+45

223

222

221

220 219

218

217

216

215

214

213

212

211

210 209 208

+46

239

238

237

236 235

234

233

232

231

230

229

228

227

226 225 224

+47

255

254

253

252 251

250

249

248

247

246

245

244

243

242 241 240

Bit

Name

Status

Manipulated

by

Unit operation

---

Target Node PLC
Error Flags

ON

Unit

A fatal or non-fatal error occurred
in the corresponding PLC.

OFF

Unit

No error occurred in the PLC.

15 14 13 12 11 10 9 8

7

6 5

4

3

2

1

0

+48

15 14 13

12 11 10 9 8 7 6 5 4 3 2 1

0

+49

31 30 29

28 27 26 25 24 23

22 21 20 19

18

17 16

+50

47 46 45

44 43 42 41 40 39

38 37 36 35

34

33 32

+51

63 62 61

60 59 58 57 56 55

54 53 52 51

50

49 48

+52

79 78 77

76 75 74 73 72 71

70 69 68 67

66

65 64

+53

95 94 93

92 91 90 89 88 87

86 85 84 83

82

81 80

+54

111

110

109

108 107

106

105

104

103

102

101

100

99

98

97 96

+55

127

126

125

124 123

122

121

120

119

118

117

116

115

114 113 112

+56

143

142

141

140 139

138

137

136

135

134

133

132

131

130 129 128

+57

159

158

157

156 155

154

153

152

151

150

149

148

147

146 145 144

+58

175

174

173

172 171

170

169

168

167

166

165

164

163

162 161 160

+59

191

190

189

188 187

186

185

184

183

182

181

180

179

178 177 176

+60

207

206

205

204 203

202

201

200

199

198

197

196

195

194 193 192

+61

223

222

221

220 219

218

217

216

215

214

213

212

211

210 209 208

+62

239

238

237

236 235

234

233

232

231

230

229

228

227

226 225 224

+63

255

254

253

252 251

250

249

248

247

246

245

244

243

242 241 240