A.1.6 Instruction Types

The SC140 instruction set is organized into the following instruction types, specified at the top of every
instruction definition in this Appendix:

DALU Instructions- perform operations on the data registers D0-D15 using the DALU execution units
(MAC and BFU). All DALU instructions are listed in Table A-7 and Table A-8. The architecture is
described in

Section 2.2.1, “DALU Architecture,”

on page 2-6.

AGU Instructions- perform operations using the AGU execution units (AAU and BMU) and the program
sequencer unit. All the AGU instructions are listed in Table A-9 through Table A-15. The architecture is
described in

Section 2.3.1, “AGU Architecture,”

on page 2-31.

BMU Instructions - are a subset of AGU instructions that perform atomic read-modify-write operations
on registers or memory locations. They execute in the BMU. All BMU instructions are listed in
Table A-12. The architecture is described in

Section 2.3.6, “Bit Mask Instructions,”

on page 2-49.

Although the BMU instructions are a subset of AGU instructions, they are presented in this Appendix with
the other types for greater visibility, and to make them easier to find.

PREFIX Instructions - support conditional execution of other instructions and NOP insertion for time
and space padding. They have unique properties since their binary form is a prefix encoding. They are
decoded by the dispatcher, but are not dispatched to an execution unit. All PREFIX instructions are listed
in Table A-16.

A.1.6.1 Instruction Sub-types

The instruction types can be further divided into sub-types as follows:

DALU Instruction Sub-types

Data arithmetic (including multiply-accumulate) instructions are listed in Table A-7 and described
in

Section 2.2.1.2, “Multiply-Accumulate (MAC) Unit,”

on page 2-10.

Logical (including bit-field) instructions are listed in Table A-8 and described in

Section 2.2.1.3,

“Bit-Field Unit (BFU),”

on page 2-12.

AGU Instruction Sub-types

Address arithmetic instructions (AAU) are listed in Table A-9 and described in

Section 2.3.1, “AGU

Architecture,”

on page 2-31.

Move instructions are listed in Table A-10 and described in

Section 2.3.7, “Move Instructions,”

on

page 2-51.

Stack Support instructions are listed in Table A-11 and described in

Section 5.5, “Stack Support,”

on

page 5-32.

Bit-Mask (BMU) instructions are listed in Table A-12 and described in

Section 2.3.6, “Bit Mask

Instructions,”

on page 2-49.

Non-loop change-of-flow (non-loop COF) instructions are listed in Table A-13 and described in

Section 5.3.2, “Change-Of-Flow Instruction Timing,”

on page 5-17.

Loop control instructions are listed in Table A-14 and described in

Section 5.4.6, “Loop Control

Instructions,”

on page 5-29.

— Loop change-of-flow instructions are also listed in Table A-14 and are described in

Section 5.3.2, “Change-Of-Flow Instruction Timing,”

on page 5-17.

Program control instructions are listed in Table A-15 and described in

Section 5.7.1, “Processing

State Change Instructions,”

on page 5-41.

Advertising