Function library, Positioning control – Lenze EVS9332xP User Manual

Page 102

Advertising
background image

Function library

Positioning control

3.4.11

Program operation

3−74

l

EDSVS9332P−EXT DE 2.0

Status Started−break"

l

Program processing is started but is interrupted by controller inhibit, QSP, TRIP, mains failure,
Fail−QSP or manual control (interruption). In order to continue the program processing a new
start edge is required.

l

Status output POS−STARTED = HIGH and

l

POS−RUNNING = LOW (for firmware version

³ 2.5)

l

Positioning status (C1283) = Started break".

Tip!

l

Firmware version

³2.5:

The states "Started" and "Started−break" can be distinguished by the new status output

POS−RUNNING".

l

Firmware version < 2.5:
When the stand−by operation is activated, "Started−break" cannot be identified!
The states Started" and Started−break" can only be distinguished via the positioning status
(C1283).

Stopped" status

l

Program and drive stopped, or drive will be stopped.

l

Status output POS−STOPPED = HIGH,

l

Positioning status (C1283) = Stopped",
or Stopped−rem", if C1280.B1 = 1 (GDC control),
or Stopped−dig", if input POS−PRG−STOP = HIGH,

Prg reset" status

l

Program processing is aborted and the drive is stopped. Actual PS No. (POS−ACT−PS−NO) is
set to "program end".

l

Output POS−RESETED = HIGH,

l

Output POS−ENDED = HIGH,

l

Positioning status (C1283) = Prg−Reset−rem", if C1280.B2 = 1 (GDC control),
or Prg−Reset−dig", if input POS−PRG−RESET = HIGH,

l

Current PS No. (POS−ACT−PS−NO) = 0 (program end)

Advertising