Homing modes 8 and 9, Function library, Positioning control – Lenze EVS9332xP User Manual

Page 82

Advertising
background image

Function library

Positioning control

3.4.8

Homing

3−54

l

EDSVS9332P−EXT DE 2.0

3.4.8.8

Homing modes 8 and 9

Purpose

l

Homing in all positioning modes (C1210 = 0, 1, 2).

l

Use of touch probe if the index pulse does not appear at the same place in a reproducible
form due to the mechanical constellation. The index signal can also be mechanically shifted
after a motor replacement.

l

The touch probe must be situated in direction of movement. The TP must not be assigned
before starting homing.

Directly travel to TP signal

Mode 8: Traversing direction to the positive end of the travel range limit switch

Set C1213 = 8.

Home position

TP signal

9300pos055

Fig. 3−20

Move to TP signal

The following settings are necessary:

l

Select terminal for TP initiator via C1214.

– C1214 = 1

¢ terminal X5/E1.

– C1214 = 2

¢ terminal X5/E2.

– C1214 = 3

¢ terminal X5/E3.

– C1214 = 4

¢ terminal X5/E4 (This setting is recommended by LENZE).

l

Select signal of the TP input via C1215/x.

– C1215/x = 0

¢ LOW−HIGH edge.

– C1215/x = 1

¢ HIGH−LOW edge.

Function sequence

l

Move to the TP signal with homing speed (C1242) towards positive end of travel range limit
switch.

l

The first TP signal determines the reference point.

Mode 9: Traversing direction to negative end of travel range limit switch

Set C1213 = 9.

Function sequence

l

As "Traversing direction to positive end of travel range limit switch", but the drive moves
towards the negative end of travel range limit switch.

Advertising