62 multi-axis synchronisation (sync1), Possible axis synchronisations, Multi−axis synchronisation (sync1) – Lenze EVS9332xP User Manual

Page 288: Function library, Function blocks, 62 multi−axis synchronisation (sync1), Function

Advertising
background image

Function library

Function blocks

3.5.62

Multi−axis synchronisation (SYNC1)

3−260

l

EDSVS9332P−EXT DE 2.0

3.5.62

Multi−axis synchronisation (SYNC1)

Purpose

Synchronises the control program cycle of the drives to the cycle of a master control.

S Y N C 1

S Y N C 1 - I N 1

S Y N C 1 - I N 2

S Y N C 1 - I N 3

S Y N C 1 - S T A T

C 1 1 2 7

C 1 1 2 8

C 1 1 2 9

C 1 1 2 4

C 1 1 2 5

C 1 1 2 6

X 5 - E 5

S Y N C 1 - O U T 1

S Y N C 1 - O U T 2

S Y N C 1 - O U T 3

C L K

X 4

C 1 1 2 3 / 1

C 1 1 2 3 / 2

C 1 1 2 1 / 2

C 1 1 2 2

C 1 1 2 1 / 1

C 1 1 2 0

C 0 3 6 3

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

SYNC1−IN1

a

C1127

dec [inc]

C1124

1

1000

SYNC1−IN2

ph

C1128

dec [inc]

C1125

3

1000

SYNC1−IN3

a

1129

dec

C1126

1

1000

SYNC1−STAT

d

After the synchronisation is completed,
SYNC1−STAT switches to HIGH.
If the synchronisation is quit,
SYNC1−STAT switches to LOW.

SYNC1−OUT1

phd

Cannot be used for angle−accurate
speed/angle difference transmission

SYNC1−OUT2

ph

With interpolation, for cyclically
synchronised position information

SYNC1−OUT3

a

With interpolation, for analog values

Function

l

Possible axis synchronisations (chapter 3.5.62.1)

l

Cycle times (chapter 3.5.62.2)

l

Phase displacement (chapter 3.5.62.3)

l

Synchronisation window for synchronisation via terminal (SYNC WINDOW) (chapter 3.5.62.4)

l

Correction value of phase controller (SYNC CORRECT) (chapter 3.5.62.5)

l

Fault indications (chapter 3.5.62.6)

l

Configuration examples (chapter 3.5.62.7)

l

Scaling (chapter 3.5.62.8)

3.5.62.1

Possible axis synchronisations

Operating mode

Code

Value

Function

C1120

0

FB without function.
Assigns the data at the inputs directly to the outputs.

1

CAN Sync active
Synchronises the controllers to the sync telegram of the system bus.

2

Terminal Sync active
Synchronises the controllers to the sync signal of terminal X5/E5.

Advertising