Function library

Positioning control

3.4.6

Control structure

3−43

l

EDSVS9332P−EXT DE 2.0

Important signals for adjusting the control loops

The following signals are especially suitable for evaluating the positioning behaviour and control
features:

l

POS−NOUT: Speed setpoint, 100 %

º n

max

(C0011)

l

MCTRL−NACT: Actual speed value, 100 %

º n

max

(C0011)

l

MCTRL−MSET2: Actual torque, 100 %

º M

max

(C0057)

l

POS−POUT−NORM: Actual following error, 100 %

º Following error tolerance (C1218/1)

Tip!

The code table can be found in the system manual, document number EDSVS9332P.