20 analog-phase converter (convaph), Analog−phase converter (convaph), Function library – Lenze EVS9332xP User Manual

Page 176: Function blocks, 20 analog−phase converter (convaph), Function, Conversion according to formula, Convaph2

Advertising
background image

Function library

Function blocks

3.5.20

Analog−phase converter (CONVAPH)

3−148

l

EDSVS9332P−EXT DE 2.0

3.5.20

Analog−phase converter (CONVAPH)

Conversion of an analog value into a phase signal.

CONVAPH1

CONVAPH1

CONVAPH1-OUT

C1594

CONVAPH1-IN

C1593

C1591

C1590

± 2

30

-1

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

CONVAPH1−IN

a

C1594

dec

C1593

1

CONVAPH1−OUT

ph

Limited to

±2

30

−1

Function

l

Conversion with adaptation through multiplier and divisor.

l

Conversion according to formula:

CONVAPH1–OUT

+ CONVAPH1–IN @ C1590

C1591

@ 16384

100%

CONVAPH2

CONVAPH2

CONVAPH2-OUT

C1599

CONVAPH2-IN

C1598

C1596

C1595

± 2

30

-1

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

CONVAPH2−IN

a

C1599

dec

C1598

1

CONVAPH2−OUT

ph

Limits to

±2

30

−1

Function

l

Conversion with adaptation using multiplier and divisor.

l

The conversion is performed according to the formula:

CONVAPH1

* OUT + CONVAPH1 * IN @ C1595

C1596

@ 16384

100%

Advertising