Prg. fct. switch output before positioning, Prg. fct. switch output after positioning, Function library – Lenze EVS9332xP User Manual

Page 114: Positioning control

Advertising
background image

Function library

Positioning control

3.4.13

Program sets (PS)

3−86

l

EDSVS9332P−EXT DE 2.0

3.4.13.8

Prg. fct. Switch output before positioning"

Purpose

Setting or resetting a digital output signal (POS−PFO), for instance, to control a machine function
before positioning starts.

9300pos014

Fig. 3−35

Diagram − Switch output

Function

l

Selection of any PFO under C1320/x. It is also possible to switch all PFO at the same time or
in groups of 8.

l

Selection of the signal level (setting or resetting) under C1321/x.

l

32 PFO are available (see POS−PFO).

l

GDC input: Programming" dialog

l

Default setting: not active

3.4.13.9

Prg. fct. Switch output after positioning"

Purpose

Like Switch output before positioning".

Function

l

Selection of any PFO under C1322/x. It is also possible to switch all PFO at the same time or
in groups of 8.

l

Selection of the signal level (setting or resetting) under C1323/x.

l

32 PFO are available (see POS−PFO).

l

GDC input: Programming" dialog

l

Default setting: not active

Tip!

If an output is to be set and reset before a positioning process, the output will not be switched if no
positioning has taken place or the target position has been reached in the same cycle. As a remedy
the output can be reset in one of the following PS. The output will then be switched for at least one
cycle.