Application examples, 3 example 3: path control – Lenze EVS9332xP User Manual

Page 322

Advertising
background image

Application examples

4.3

Example 3: Path control

4−12

l

EDSVS9332P−EXT DE 2.0

Adaptation to the example by extending the basic configuration

Please establish the following connections:

POS−MANU−NEG

´

CAN−IN2.B9

POS−MANU−POS

´

CAN−IN2.B10B1

OR1−IN1

´

FIXED0

OR1−IN2

´

FIXED0

POS−LIM−NEG

´

DIGIN1

POS−LIM−POS

´

DIGIN2

POS−MANUAL

´

CAN−IN2.B11

POS−LOOP−INH

´

CAN−IN2.B4

POS−ABS−SET

´

CAN−IN2.B4

POS−PSET−SWT

´

NOT2−OUT

NOT2−IN

´

CAN−IN2.B11

Function of the ’Path control’ after changing the configuration

Input

Level

Function

CAN−IN2.B4

HIGH

Switch off position control circuit

Accept position setpoint as actual position

CAN−IN2.B9

HIGH

Manual operation in negative traversing
direction

CAN−IN2.B10

HIGH

Manual operation in positive traversing
direction

CAN−IN2.B11

HIGH

Activate manual operation

Advertising