Function library

Function blocks

3.5.68

Variable table Waiting time (VTTIME)

3−280

l

EDSVS9332P−EXT DE 2.0

Function

A total of 34 table positions are available.

l

Enter fixed time value under C1305.

– 30 table positions (VTTIME−No1 ... VTTIME−No30) are available.

– Subcodes (C1305/1 ... C1305/30) define the table position number.

l

Enter variable time values under VTTIME−INx.

– 4 table positions (VTTIME−No31 ... VTTIME−No34) are available.

– Signal input via function blocks.

– The time values must be transmitted to the table positions before the program set starts

and has access to it.

l

C1387 displays the time values on the table positions.

– Select table position (C1387/1 ... C1387/34) with subcode.

Note!

Entries into the processing table are necessary only if the FB inputs and outputs are used.