3.5.50

Oscilloscope function (OSZ)

3−236

l

EDSVS9332P−EXT DE 2.0

Function

Description

Selection

Code

Memory size

C0744

0 ... 6

Set memory depth of the data memory

– Max. size of the data memory: 8192 measured values

¢ 16384 bytes (C0744 = 6)

– Min. size of the data memory: 512 measured values

¢ 1024 bytes (C0744 = 0)

– Changing the memory depth from 512 to 8192 measured values/step
– A memory depth which is optimally adapted to the corresponding measuring task

reduces the data transmission time.

Information on
saving

Information on saving the measured values in the data memory
The FB saves the data in a ring format. For reconstructing the chronological signal
sequence the following three "graphic points" are marked.

C0749/1

Measured value no. of the instant of abortion

C0749/2

Measured value no. of the instant of triggering

C0749/3

Measured value no. of the instant of completion

Signal characteristic

before triggering

Trigger level

Instant of triggering

Memory content

Signal characteristic after triggering

Measured signal

Fig. 3−182

Example: Trigger level and trigger delay with approx. −30 % of pre−triggering

Signal characteristic

before triggering

Trigger delay

Trigger level

Instant of triggering

Memory content

Signal characteristic after triggering

Measured signal

Fig. 3−183

Example: Trigger level and trigger delay with approx. −30 % of post−triggering