Function library

Function blocks

3.5.43

Internal motor control (MCTRL)

3−209

l

EDSVS9332P−EXT DE 2.0

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

MCTRL−PHI−SET

ph

C0908

dec [inc]

C0894

3

1000

Angle controller input for difference of
setpoint angle to actual angle

MCTRL−N−SET

a

C0906/1

dec [%]

C0890

1

5050

Speed setpoint input

MCTRL−M−ADD

a

C0906/2

dec [%]

C0891

1

1000

Additional torque setpoint or torque
setpoint

MCTRL−LO−MLIM

a

C0906/3

dec [%]

C0892

1

5700

Lower torque limitation in % of C0057

MCTRL−HI−MLIM

a

C0906/4

dec [%]

C0893

1

19523

Upper torque limitation in % of C0057

MCTRL−PHI−LIM

a

C0906/5

dec [%]

C0895

1

1006

Influence of angle controller in % of nmax
C0011

MCTRL−N2−LIM

a

C0906/6

dec [%]

C0896

1

1000

Lower speed limit at speed limitation

MCTRL−FLDWEAK

a

C0906/7

dec [%]

C0898

1

1006

Motor excitation

MCTRL−I−SET

a

C0906/8

dec [%]

C0901

1

1006

Input for setting the I component of the
speed controller

MCTRL−P−ADAPT

a

C0906/9

dec [%]

C0903

1

1006

Influence in % on V

P

of C0254, the absolute

value is processed (without sign)

MCTRL−PHI−ON

d

C0907/1

bin

C0897

2

1000

HIGH = Activation of angle controller

MCTRL−N/M−SWT

d

C0907/2

bin

C0899

2

1000

LOW = active speed control
HIGH = active torque control

MCTRL−QSP

d

C0907/3

bin

C0900

2

10250

HIGH = drive performs QSP

MCTRL−I−LOAD

d

C0907/4

bin

C0902

2

1000

HIGH = I component of the n−controller is
accepted by MCTRL−I−SET

MCTRL−QSP−OUT

d

HIGH = drive performs QSP

MCTRL−NSET2

a

In % of n

max

(C0011)

MCTRL−MMAX

d

HIGH = speed controller operates within the
limits

MCTRL−MSET2

a

In % of M

max

(C0057)

MCTRL−MACT

a

In % of M

max

(C0057)

MCTRL−IACT

a

MCTRL−IACT = 100 % = C0022

MCTRL−IMAX

d

HIGH = drive operates at the current limit
C0022

MCTRL−DCVOLT

a

100 % = 1000 V

MCTRL−LOAD−I2xt

a

I

2

× t utilisation of the motor in %

MCTRL−UTILIZATION

a

Device utilisation I × t in %

MCTRL−PHI−ANA

a

Actual angle value as analog signal
90° = 100 %

MCTRL−PHI−ACT

phd

MCTRL−NACT

a

In % of n

max

(C0011)

MCTRL−PHI−ANG

ph

65536 inc = one revolution