8 homing, Homing, Function library – Lenze EVS9332xP User Manual

Page 74: Positioning control

Advertising
background image

Function library

Positioning control

3.4.8

Homing

3−46

l

EDSVS9332P−EXT DE 2.0

3.4.8

Homing

Determination of the mechanical reference point for measuring systems.

After homing, the drive is in a defined position.

Functions

l

Homing (

¶ 3−46)

l

Homing end (

3−47)

l

Homing status (

¶ 3−48)

l

Homing modes (

3−49)ff.

l

Second homing speed (

¶ 3−56)

l

Set homing value(

3−57)

3.4.8.1

Homing

Purpose

Definition of the reference point in the absolute or relative positioning mode.

Function

l

Selection of a sequence suitable for homing (

¶ 3−49).

l

Setting of the homing speed under C1242

– Setting of a second homing speed under C1241 (if necessary) (

3−56)

l

Setting of the homing acceleration under C1251

l

Definition of the final homing point under C1209.

l

Execution of homing in

– Manual operation via "manual referencing" (

¶ 3−67).

– Program operation (GDC dialog "Programming" under PS mode" or selection under

C1311/x = 3, program set mode)

Homing procedure

l

The homing status POS−REF−OK is reset (see (

¶ 3−48)) and the current reference offset

initialised using the value entered under C1225.

l

Homing is started and carried out according to the mode selected under C1213.

l

If the reference point is found, the home position (C1227) is set and the reference offset
(C1225) is added. The position data now refer to the real zero point (see Fig. 3−12).

l

The homing status POS−REF−OK is set.