3.4.4

Measuring systems

3−35

l

EDSVS9332P−EXT DE 2.0

3.4.4.1

Measuring systems and zero shifts

9300POS007

0

a c t . h o m e p o s i t i o n

C 1 2 2 7 ( C 1 2 2 0 / 8 )

L i m i t p o s i t i o n

n e g a t i v e

L i m i t p o s i t i o n

p o s i t i v e

C 1 2 2 4

C 1 2 2 3

0

a c t . h o m e o f f s e t

C 1 2 2 5 ( C 1 2 2 0 / 7 )

a c t . t a r g e t p o s i t i o n

C 1 2 2 0 / 1

H o m e p o s i t i o n

R e a l m e a s u r i n g s y s t e m

M a c h i n e

m e a s u r i n g

s y s t e m

Fig. 3−12

Measuring systems for absolute positioning and zero point shifting

Shifting of machine zero

Purpose

l

The reference run is to be carried out on one side of the traversing range when it is too time
consuming to approach the machine zero.

Function

l

Via the home position (C1227) the machine zero point is shifted with regard to the reference
point. The home position is set at the reference point so that with a positive home position the
machine zero point is situated in negative direction.

l

The home position (C1227) will only be accepted as actual home position" when being in

reference run" or set reference point" mode.

l

The effective actual home position" is indicated under C1220/8 and C1221/8.