Function library

Function blocks

3.5.23

Phase conversion (CONVPHPH2)

3−155

l

EDSVS9332P−EXT DE 2.0

3.5.23

Phase conversion (CONVPHPH2)

Purpose

Conversion of a phase signal with dynamic fracture.

C O N V P H P H 2

C O N P H P H 2 - O U T

C O N V P H P H 2 - I N

C 1 1 3 7

C 1 1 3 2

C O N V P H P H 2 - N U M

C 1 1 3 5 / 1

C 1 1 3 0 / 1

C O N V P H P H 2 - D E N

C 1 1 3 5 / 2

C 1 1 3 0 / 2

x

y

C 1 1 3 1

C 1 1 3 6

C O N V P H P H 2 - A C T

1
0

0

Fig. 3−108

Phase conversion (CONVPHPH2)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

CONVPHPH2−IN

ph

C1137

dec [inc]

C1132

3

CONVPHPH2−NUM

a

C1135/1

dec

C1130/1

1

Numerator

CONVPHPH2−DEN

a

C1135/2

dec

C1130/2

1

Denominator (with absolute−value generation)

CONVPHPH2−ACT

d

C1136

bin

C1131

2

CONVPHPH2−OUT

ph

Without limitation, residual value considered

Function

Caution!

The conversion result is not limited. The result must not exceed the range of ±2147483647.

l

C1131 = HIGH

– The phase signal at CONVPHPH2−IN is evaluated with the factor from C1135/1 / C1135/2.

l

C1131 = LOW

– The value 0 is evaluated with the factor from C1135/1 / C1135/2.