68 variable table waiting time (vttime), Variable table waiting time (vttime), Function library – Lenze EVS9332xP User Manual

Page 307: Function blocks, Stop

Advertising
background image

Function library

Function blocks

3.5.68

Variable table Waiting time (VTTIME)

3−279

l

EDSVS9332P−EXT DE 2.0

3.5.68

Variable table Waiting time (VTTIME)

One function block (VTTIME) is available.

Purpose

Store values for waiting times. They are used as delays for the function "Waiting time" in the
positioning program.

VTTIME-IN1

VTTIME

C1358/1

C1359/1

VTTIME-IN2

C1358/2

C1359/2

VTTIME-IN3

C1358/3

C1359/3

VTTIME-IN4

C1358/4

C1359/4

C1305/1

VTTIME-OUT1

C1305/2

VTTIME-OUT2

C1305/3

VTTIME-OUT3

C1305/4

VTTIME-OUT4

C1305/5

...

C1305/30

VTTIME-No 1

VTTIME-No 2

VTTIME-No 3

VTTIME-No 4

VTTIME-No 5

VTTIME-No 30

VTTIME-No 31

VTTIME-No 32

VTTIME-No 33

VTTIME-No 34

C1387/x

...

Fig. 3−221

Function block VTTIME

Stop!

If times >32767 ms are entered under C1305/1 to C1305/4 the outputs VTTIME−OUT1 ...
VTTIME−OUT4 must no longer be used.

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

VTTIME−IN1

a

C1359/1

dec [inc]

C1358/1

3

·

Generates the absolute value for negative values.

·

Value = 100 % = 16384 ms

·

Limits the value to 32767 ms

·

Display: 1 inc = 1 ms

VTTIME−IN2

a

C1359/2

dec [inc]

C1358/2

3

VTTIME−IN3

a

C1359/3

dec [inc]

C1358/3

3

VTTIME−IN4

a

C1359/4

dec [inc]

C1358/4

3

VTTIME−OUT1

a

1 inc = 1 ms

VTTIME−OUT2

a

1 inc = 1 ms

VTTIME−OUT3

a

1 inc = 1 ms

VTTIME−OUT4

a

1 inc = 1 ms

Advertising