Absolute positioning, Function library, Positioning control – Lenze EVS9332xP User Manual

Page 60

Advertising
background image

Function library

Positioning control

3.4.3

Positioning modes (C1210)

3−32

l

EDSVS9332P−EXT DE 2.0

3.4.3.2

Absolute positioning

9300POS025

S1

S2

S3

Home position

Limit position
negative

C1224

C1223

End of travel switch
positive direction

POS-LIM-NEG

POS-LIM-POS

POS-REF-MARK

End of travel switch
negative direction

Limit position
positive

Fig. 3−10

Example of a machine with finite traversing range

Purpose

l

Use in applications with finite traversing range, e. g. in warehousing or handling machines.

Function

l

Set positioning mode (C1210) = 0 (default setting)

l

Before starting a positioning drive homing must be carried out (output POS−REF−OK = 1,
homing status C1284 = REF−OK"). By homing the reference point of the measuring system to
the machine is determined (

¶ 3−46)

l

In the absolute positioning mode absolute and relative target positions can be approached.
There are two measuring systems (

¶ 3−34):

– the machine measuring system and

– the real measuring system

l

The travel range limit switches are located in front of the mechanical stops. They prevent the
drive from touching the stops.

l

Adjustable position limiting values (C1223, C1224) prevent the travel range limit switches from
being approached under normal operating conditions. A target position located outside the
position limiting value is not approached. In this case a fault is indicated (P04, P05).