Homing modes 0 and 1, 3−49)f, Function library – Lenze EVS9332xP User Manual

Page 77

Advertising
background image

Function library

Positioning control

3.4.8

Homing

3−49

l

EDSVS9332P−EXT DE 2.0

3.4.8.4

Homing modes 0 and 1

Purpose

l

Simple homing in all positioning modes (C1210 = 0, 1, 2).

l

The homing switch (POS−REF−MARK) must be in direction of the movement.

Move to reference point via homing switch

Mode 0: Traversing direction to positive end of travel range limit switch

Set C1213 = 0.

Homing switch (POS-REF-MARK)

Zero pulse/zero position

Home position

Direction

9300pos052

Fig. 3−16

Move to reference point via homing switch

Function sequence

l

Move to the reference point with homing speed (C1242) towards positive end of travel range
limit switch overtravelling the homing switch.

l

The reference point is at the first zero pulse / zero position of the position encoder after leaving
the homing switch.

The drive can be on the homing switch before homing.

Mode 1: Traversing direction to negative end of travel range limit switch

Set C1213 = 1.

Function sequence

l

Like mode 0, but the drive traverses in negative direction to travel range limit switch.