Function library, Function blocks, 12 bcd decade switch (bcd) – Lenze EVS9332xP User Manual

Page 146: Bcd2

Advertising
background image

Function library

Function blocks

3.5.12

BCD decade switch (BCD)

3−118

l

EDSVS9332P−EXT DE 2.0

BCD2

C1710/2

C1713
C1714

CTRL

+

+

C1715

S&H

C1719/6

BCD2-LOAD

C1718/6

C1710/1

Code/Subcode

(Cxxxx/yyy)

C1717

C1716

BCD2-BUSY

BCD2

³1

C1719/7

BCD2-BUSY-IN

C1718/7

³1

C1719/8

BCD2-FAIL-IN

C1718/8

BCD2-FAIL

C1719/2

BCD2-DATA1

C1718/2

C1719/3

BCD2-DATA2

C1718/3

C1719/4

BCD2-DATA3

C1718/4

C1719/5

BCD2-DATA4

C1718/5

C1719/1

BCD2-READ

C1718/1

BCD2-SIGN
BCD2-SEL1
BCD2-SEL2
BCD2-SEL3
BCD2-SEL4
BCD2-SEL5
BCD2-SEL6
BCD2-SEL7
BCD2-SEL8

BCD2-NEW-DATA

BCD2-EOT

BCD2-DATA-FLT

C1712

C1711

BCD-

LOGIC

2

0

2

1

2

2

2

3

Fig. 3−74

Function block BCD2

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

BCD2−DATA1

d

C1719/2

bin

C1718/2

2

Data input (LSB)

BCD2−DATA2

d

C1719/3

bin

C1718/3

2

Data input

BCD2−DATA3

d

C1719/4

bin

C1718/4

2

Data input

BCD2−DATA4

d

C1719/5

bin

C1718/5

2

Data input (MSB)

BCD2−READ

d

C1719/1

bin

C1718/1

2

Only required for handshake mode:

·

Signal must be applied at the controller for at least
2 ms.

·

LOW−HIGH edge starts the data transmission for a
BCD.

BCD2−LOAD

d

C1719/6

bin

C1718/6

2

LOW−HIGH edge = Write data to the code.

BCD2−BUSY−IN

d

C1719/7

bin

C1718/7

2

Generating a collective busy signal

BCD2−FAIL−IN

d

C1719/8

bin

C1718/8

2

Generating a collective fail signal

BCD2−SIGN

d

HIGH = Read sign.

BCD2−SEL1

d

HIGH = Read 1st BCD.

BCD2−SEL2

d

HIGH = Read 2nd BCD.

BCD2−SEL3

d

HIGH = Read 3rd BCD.

BCD2−SEL4

d

HIGH = Read 4th BCD.

BCD2−SEL5

d

HIGH = Read 5th BCD.

BCD2−SEL6

d

HIGH = Read 6th BCD.

BCD2−SEL7

d

HIGH = Read 7th BCD.

BCD2−SEL8

d

HIGH = Read 8th BCD.

BCD2−NEW−DATA

d

HIGH = BCD accepted, transmit next BCD.

BCD2−EOT

d

HIGH = all BCDs read or "CANCEL" recognised.

BCD2−DATA−FLT

d

HIGH = BCD code (see chapter 3.5.12.1).

BCD2−BUSY

d

HIGH = Data are being transmitted to code.

BCD2−FAIL

d

HIGH = Data transmission to code is faulty.

Advertising