Application examples

4.1

Example 1: Dosing system

4−5

l

EDSVS9332P−EXT DE 2.0

Travel profiles

Time

Description

1, 6

Container has almost reached the target position

·

Brake feed

2, 7

Container in target position

·

Start filling (observe dead time)

5, 10

Filling completed

·

Start feed, filled container leaves positioning sensor, empty container is positioned

Dosing drive B

PS

Time

Description

01

0 − 2

Waiting for input POS−PFI 32, signal at X5/E4 (H level). The feed drive starts the dosing drive if the container is
positioned.

2 − 5

Filling according to program set parameters

5

Start feed (drive A): switch POS−PFO1, X5/A4; L level

·

Jump to program set 1 (PS01)

Transport drive FEED A

PS

Time

Description

01

2 − 5

Wait for input POS−PFI = 0 level

5 − 6

Feed until TP(E4) responds

6 − 7

Cover residual path and stop

7

Start dosing drive PFO 01 = H: A4 = High, then jump to PS01

02

Is required to complete the program.