Overview of the codes for the evaluation of the read data and for the selection of the target code.

Function

BCD1

BCD2

BCD3

Output signal (DIS)

C1700/1

C1710/1

C1720/1

BCD result of the read data (DIS)

C1700/2

C1710/2

C1720/2

Target code

C1701

C1711

C1721

Subcode of the target code

C1702

C1712

C1722

Numerator (evaluation of the result)

C1703

C1713

C1723

Denominator (evaluation of the result)

C1704

C1714

C1724

Offset (evaluation of the result)

C1705

C1715

C1725

Function

l

BCD decade switch

l

Data inputs

l

Signal processing

l

"CANCEL" function

l

"RESET" function

l

BCD decade switch

l

Complete BCD reading

l

BCD mode

3.5.12.1

Data inputs

Evaluation of the read data:

BCDx−Datax

MSB ... LSB

BCD ABSOLUTE VALUE

BCD−SIGN

0000

0

(+)

0001

1

0010

2

0011

3

0100

4

0101

5

0110

6

0111

7

1000

8

(−)

1001

9

1010

CANCEL

CANCEL

1011

RESET

RESET

1100

BCD error

BCD error

1101
1110
1111