Function library, Positioning control, Purpose – Lenze EVS9332xP User Manual

Page 119

Advertising
background image

Function library

Positioning control

3.4.14

POS−TP (Touch−probe saving of the actual position value)

3−91

l

EDSVS9332P−EXT DE 2.0

3.4.14

POS−TP (Touch−probe saving of the actual position value)

Purpose

l

Saving of the actual position value (POS−ACTPOS) is interrupt−controlled, the reaction times
are very short.

POS-TP1-ENABL

C1361/11

C1360/11

E1

X5

POS-TP2-ENABL

C1361/12

C1360/12

E2

X5

POS-TP3-ENABL

C1361/13

C1360/13

E3

X5

POS-TP4-ENABL

C1361/14

C1360/14

E4

X5

CTRL

POS-TP1-ENABLED

POS-TP1-RECOGN

POS-TP2-ENABLED

POS-TP2-RECOGN

POS-TP3-ENABLED

POS-TP3-RECOGN

POS-TP4-ENABLED

POS-TP4-RECOGN

VTPOS-No 101

VTPOS-No 104

VTPOS-No 102

VTPOS-No 104

POS-TP

Homing,
Touch-Probe - Positioning

C0430/1

C0430/2

C0430/4

C0430/3

9300pos017

l

The values saved are available as position−targets for positioning or, for instance, for length
calculation with arithmetic function blocks.

Fig. 3−40

Table inputs, outputs

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

POS−TP1−ENABL

d

C1361/11

bin

C1360/11

2

HIGH = activate TP saving

POS−TP2−ENABL

d

C1361/12

bin

C1360/12

2

HIGH = activate TP saving

POS−TP3−ENABL

d

C1361/13

bin

C1360/13

2

HIGH = activate TP saving

POS−TP4−ENABL

d

C1361/14

bin

C1360/14

2

HIGH = activate TP saving

POS−TP1−ENABLED

d

Indicates the enabling of the TP input

POS−TP1−RECOGN

d

TP signal detected at terminal X5/E1

POS−TP2−ENABLED

d

Indicates the enabling of the TP input

POS−TP2−RECOGN

d

TP signal detected at terminal X5/E2

POS−TP3−ENABLED

d

Indicates the enabling of the TP input

POS−TP3−RECOGN

d

TP signal detected at terminal X5/E3

POS−TP4−ENABLED

d

Indicates the enabling of the TP input

POS−TP4−RECOGN

d

TP signal detected at terminal X5/E4

Function

The following table positions are assigned to the TP inputs:

l

TP1

¢ X5/E1 and saves in table position VTPOS−No 101.

l

TP2

¢ X5/E2 and saves in table position VTPOS−No 102.

l

TP3

¢ X5/E3 and saves in table position VTPOS−No 103.

l

TP4

¢ X5/E4 and saves in table position VTPOS−No 104.

The following settings are required:

Code

Subcode

Function

C1215

1 ... 4

Determine signal edge for the initiator at the TP input.

·

0 = LOW−HIGH edge

·

1 = HIGH−LOW edge

·

Subcode 1 ... 4 for terminal X5/E1 ... X5/E4

C1360

11 ... 14

Configuration of a signal source to activate the TP input.