Function library – Lenze EVS9332xP User Manual

Page 297

Advertising
background image

Function library

Function blocks

3.5.63

Teach−in in programming (TEACH)

3−269

l

EDSVS9332P−EXT DE 2.0

Function

l

The FB accepts a value (e.g. actual position) at TEACH1−L−IN.

l

A LOW HIGH edge at TEACH1−SET transmits the value TEACH1−L−IN to the selected table
position in VTPOS.

l

A LOW−HIGH edge at TEACH−NEXT selects the next table position.

– 30 table positions (VTPOS−No 71 ... VTPOS−No 100) are available.

– The number of the selected table position can be displayed via C1403.

– TEACH1−CNT transmits the number of the table position as analog signal.

l

TEACH1−CLR = HIGH resets all values in the table positions to zero and selects
simultaneously the table position VTPOS−No 71.

l

An analog signal at TEACH1−LDVAL selects directly a table position (VTPOS−No).

– Signal values < 71 = interpreted as VTPOS−No 71.

– Signal values > 100 = interpreted as VTPOS−No 100.

– TEACH1−LOAD = HIGH selects the position.

l

If the levels are applied at the same time to the digital inputs, the following priority is valid:

– TEACH1−CLR (1)

– TEACH1−LOAD (2)

– TEACH1−NEXT (3)

– TEACH1−SET (4)

Tip!

Save the target positions permanently using C0003.

Advertising